Liquid
chromatography |
Separation module, Model Alliance 2695 (Waters)
-Provides quaternary solvent high-performance
solvent delivery, integral helium sparge for
solvent conditioning, integral plunger seal-wash
system
-Uses five carousels with a total capacity of
120 vials
Pump, Model 515 HPLC (Waters)
-High precision, reliability, smooth eluent
flow, and proven performance
-Can operate in two control modes: stand-alone
module and remote control mode (under the
control of data system or external controller)
Detector, Model Coulochem III (ESA)
-Coulometric and amperometric cells can be used
to optimize performance for a given application
-Quantifies picogram to femtogram levels of
oxidizable or reducible compounds in a sample
-Saves bench space and provides a protected
environment for columns and cells with
integrated organizer module (optional
temperature control available)
Dual
l
Absorbance Detector, Model 2487 (Waters)
-Can enhance the productivity of any
chromatography laboratory with its versatile and
simple programmability, timesaving
qualification, real-time viewing of
chromatograms or spectral scans, and
dual-wavelength performance.
-Operates from 190 to 700 nm
Empower Chromatography Data Software (Waters)
Temperatura Control System (Waters)
-Temperature control module (038000) and column
heater module (038040)
-The emperature control module is an
independent, microprocessor-controlled unit
capable of simultaneously regulating and
maintaining the temperature of up to three
heaters. Each heater may be set a different
temperature
-The column heater supports up to four 30 cm
columns
Interface, Model SAT/IN
Other equipment:
Vortex, magnetic stirrers, centrifuges, etc.
|
Cell
culture |
Biological Safety Cabinets, Model BIO-II-A and
Model BIOSTAR (TELSTAR)
-Two HEPA filters
-Flow air velocity m3/h, m/s: 1100,
0.40
-Microprocessor
control and alarm system
-U.V. kit lamp
Biological Safety Cabinets, Model CYTOSTAR
(TELSTAR)
-Three HEPA filters
-Flow air velocity m3/h, m/s: 1100,
0.40
-Microprocessor
control and alarm system
-U.V. kit lamp
Direct Heat CO2 Incubator, Model 311
(THERMO FORMA)
-Interior Volume: 184.1 L
-Thermal conductivity sensor
Steri-cycle CO2 Incubator, Model 371 (THERMO
FORMA)
-Interior
Volume: 184.1 L
-HEPA filter
-Microprocessor control and alarm system
-Thermal conductivity sensor
-High heat cycle for periodic sterilization
Microscope, Model Eclipse TE2000
(Nikon)
-CFI60 infinity optical system, parfocal
distance 60mm
-External control of the microscope from a PC
-Multi-port
design enables optical input/output of light and
images from a wide variety of illumination and
detector equipment and extendable "Stratum
Structure" configuration permits the addition of
an optional light source and other attachments
within the infinity path without modifying the
microscope.
-Digital Camera
-Phase contrast
-Epi-fluorescence
-Normaski
Microscope, Model CKX41 (Olympus)
-Infinity-corrected
optical system
-Binocular
tube, inclined 30°,
interpupillary distance range: 48-75mm, diopter
adjustment by helicoid on left sleeve Tubo de
observación inclinable
-Trinocular observation tube for attaching
photo, video or digital cameras
Other equipment:
water baths with digital regulation and reading
of temperature of time, fridges, etc.
|
Biochemistry |
Sample Concentrator, Model DRI-BLOCK DB 3 (TECHNE)
-Temperature range 25°C to 100°C
-96-well microtitre block
-The hypodermic needles are set in a silicone
rubber matrix assembly enabling their positions
to be changed to accommodate different tube
configurations
-The gas chamber is suitable for use with most
gases and may be adjusted to suit the level of
liquid in the sample tubes to give even faster
evaporation times
Centrifuge, Model 22RR (BECKMAN COULTER)
-Ambient temperature range for optimum
operation: 4 to 35 °C
-Temperature setting. -10 ti + 40 °C (in 2 °C
increments)
-Set speed: 500 to 14000 rpm
Digital Sonifier, Model 250 (BRANSON)
-Digital keypad entry for parameters
-Rotary amplitude output control
-Output power is up to 200 W
-Remote terminal control
-Duty cycle: intermittent- pulse duration
adjustable (0.1 second- 59.9 seconds) or
continuous processing time
UV-Vis Spectrophotometer,
Model CARY 50 BIO (VARIAN)
-Can
perform 300 nm scans in less than a second.
-Cary win UV software
-Simple and Advanced Reads, enzyme kinetics,
wavelength scans, concentration measurements
Peristatic Pump, Model MasterFlex Digital
Console L/S Pump Drive (COLE-PARMER)
-Digital control
-1.6
to 100 r/min
Microscope, Model E400
(Nikon)
-Infinity optical system
-Coaxial
focusing
Other equipment:
Heaters, magnetic stirrers,
water baths with digital regulation and reading
of temperature of time,
ultrasonic bath, shaking water bath, pHmeter,
dry bath, vortex, fridges, etc.
|
Molecular
biology |
Thermal Cycler, Model PX2 Thermal Cycler (Thermo
Electron Corporation)
-Gradient capability for rapid protocol
-Accurate temperature control for optimal PCR
performance
-Multiple
interchangeable block options for flexible
choice of sample size
Gel Documentation System, Model ChemiDoc
Universal Hood II (BIO-RAD)
-Excitation source 254, 302, 365 nm and white
light
-Supercooled high-resolution CCD camera with 3.1
megapixel resolution
-Pixel density: 256 gray levels
-Software Quantity One
Imaging Systems, Model Molecular Imager FX Pro
Plus (BIO-RAD)
-Single and multicolour fluorescent detection by
direct laser excitation
-Chemifluorescent detection of protein blots
-Radioisotopic imaging (32P, 33P,
35S, 14C y 3H)
-Software Quantity One
Screen Erase K (BIO-RAD)
-Removes
any residual signal or background from the
imaging screen.
-Input voltages 220 V
-Imaging screen 35 x 43 cm
Semi-Dry Transfer System, Model Trans-Blot SD
Semi-Dry Cell (BIO-RAD)
-Capacity to transfer multiple gels
-Maximum gel size (W x L) 24 x 16 cm
Centrifuge, Model Allegra X-22R (BECKMAN
COULTER)
-Temperatura range: -20 to +40 °C
-Maximum speed: 22065 g/15500 rpm
Other equipment:
horizontal and vertical cells for agarose and
acrylamide gels, power supplies, microwave,
vortex, magnetics stirrers, centrifuges,
water baths with digital regulation and reading
of temperatura of time,
ultrasonic bath, shaking water bath, pHmetre,
dry bath, laboratory autoclave, fridges, etc.
|
Electrophysiology
|
Stereomicroscope, Model SMZ1000 (Nikon)
-10:1 zoom ratio,
-Total magnification: 8X to 480X
-Coaxial control knobs on both sides
-Fiber optic light source 150 W
Micromanipulator
-Cold Light illuminator
Micropipette Puller, Model P-97 (Sutter
Instrument)
-Memory storage for up to 100 programs
-Control over the time and pressure at which the
air is delivered
Microinjector, Model IM300 (Narishige)
-External pressure sources
-Inject very small volumes of liquid with great
precision.
Temperature Control System, Model TC344B
(Warner)
-Dual channel
Thermic table, Model RTC1 (Cibertec)
Preamplifier, Model Ampli 6 (Cibertec)
-Recording an electrical cellular signals
Stimulator, Model Master 8 (AMPI)
-8 channels with repetitive, single and train
outputs. All channels can be operated
independently or synchronized
-Wide time intervals between pulses/trains: from
60 micro sec to 3999 sec
Microelectrode Amplifier, Model Multiclamp 700A
(Axon)
-Intracellular and extracellular recording
Data Acquisition and Analysis, Models CD1401 and
Digidata (Axon)
Other equipment:
antivibrator table
|
Exercise
physiology |
Treadmill with O2/CO2
analyzer, Model Oxylet 4 LE 400-4 (LSI
Letica)
-Evaluate respiratory metabolism by means of
indirect calorimetry
-Optimized for rat and mice
-Highly sensitive and stable sensor for O2
and CO2
-O2 sensor technology and resolution:
laser diode absorption, 0.01% and CO2
sensor technology and resolution: infrared
spectroscopy, 0.01%
-Air flor: 150 mL/min - 2 L/min
Electromyograph, Model ME6000 (Megawin)
-8 channels
-Possibility for real time measurements or data
download
SRM Ergometer
-Cycloergometer for isoinertial
and isokinetic tests
Treadmill H/P/Cosmos Pulsar
- Speed: 0 - 40 Km/h
- Elevación: positive - negative + 25 % a - 25 %
- Running surface: 190 x 65 cm
- Motor: 3 KW / 4 HP
Ergospirometer Medisoft Ergocard
- Determination of O2 y de CO2 volumes breath by breath
- Integrated 12 channels electrocardiographic system.
- Nutritional and energy assessment
- Ventilatiry weaning evaluation
Blood Gas Analyzer, Model ABL 700 (Radiometer
Copenhagen)
-Blood simples are aspirate in Esther syringe or
capillary mode
-Measurement of ionised calcium, chloride,
bicarbonato, lactate, hematocrit, etc.
|
|